Home Catalogue Part search Parker Company Contact Inquiry cart +49 3385 520 165 0 DEEN

Home › Selection guide

Select by application, not by series number.

You know the application but not the Parker series. Narrow down what the part has to do — you get the series from the authorized range that come into question.

This pre-selection is not a sizing exercise. It rests solely on the data held in our catalogue records. Whether a given version is permissible for your operating point is decided by rated pressure, temperature, sealing material and connection in the manufacturer’s data sheet — which we supply with the quotation.
2/2-way valves

121/122 direct-operated 2/2-way solenoid valves

Parker 121K · 121V · 122K
  • 2/2-way, direct operated
  • series 121K, 121V, 122K
  • air, neutral gases and liquids
  • modular coil system, ATEX available
To the series →
2/2-way valves

221/321/322 coupled- and pilot-operated 2/2-way solenoid valves

Parker 221G · 321 · 322
  • 2/2-way, coupled or pilot operated (diaphragm/piston)
  • series 221G, 321, 322
  • water, hot water, steam; low-water-hammer types
  • standard mount or enclosed versions
Stated in the catalogue: medium temperatures up into the steam range
To the series →
3/2-way valves

131/133 direct-operated 3/2-way solenoid valves

Parker 131K · 132 · 133K · 331
  • 3/2-way, direct operated
  • series 131K, 132, 133K, 331
  • pressurise, vent, divert
  • shares coil groups with the 2-way range
To the series →
Compact valves

N74, PM128, PM146 compact solenoid valves

Parker N74 · PM128 · PM146 · 139
  • 2/2- and 3/2-way, direct operated
  • series N74, PM128, PM146, 139
  • ruby or FKM seat
  • −30 °C to +140 °C, WB/ZB coils
Stated in the catalogue: −30 °C to +140 °C
To the series →
Pilot valves for actuators

341/342 NAMUR valves (3/2- and 5/2-way)

Parker 341N · 342N
  • 3/2- and 5/2-way, NAMUR interface
  • series 341N, 342N
  • spring return or bi-stable
  • direct mounting on quarter-turn actuators
To the series →
Pilot valves for actuators

341P/345/347 piped pneumatic valves

Parker 341P · 345 · 347
  • 3/2- and 5/2-way, piped
  • series 341P, 345, 347
  • mono-stable or bi-stable (2 pilots)
  • for cylinders and actuators
To the series →
Stainless-steel valves

Stainless-steel solenoid valves (303/316L)

Parker Edelstahl 303 / 316L
  • 303 / 316L stainless steel
  • catalogue sections stainless 303 and 316L
  • 2/2-, 3/2- and NAMUR functions
  • for aggressive media and environments
To the series →
Industrial valves

Gold Ring industrial valves (series 71–73)

Parker 71215 · 71315 · 7321
  • 2/2- and 3/2-way, NPT connections
  • series 71215, 71315, 7321 et al.
  • air, water, oils, steam
  • complete valve-coil assemblies
Stated in the catalogue: air, water, oils and steam; NPT connections
To the series →
Process valves

F-series piston valves (2/2-way)

Parker 04F–20F · FS
  • 2/2-way piston valves, pilot operated
  • frame sizes 04F to 20F, FS steam line
  • air, water, light oil, steam
  • rebuild kits for all versions
Stated in the catalogue: dedicated FS steam series
To the series →
Process valves

HP-series high-pressure process valves

Parker HP113–HP344
  • 2/2- and 3-way line valves
  • series HP113–HP344
  • pressure classes 275 # to 4000 #
  • spares: stems, seats, diaphragms, packings
Stated in the catalogue: pressure classes 275 # to 4000 #, 1/2–2 inch NPT
To the series →
Angle-seat valves

PA angle-seat valves (pneumatically actuated)

Parker PA10–PA65
  • angle-seat valves, pneumatically actuated
  • DN 10 to DN 65 (3/8–2 1/2 inch)
  • spring return NC / NO
  • stainless steel, G or NPT connection
Stated in the catalogue: DN 10 to DN 65, G or NPT thread
To the series →
Pressure regulators

EPP4 electro-pneumatic pressure regulators

Parker P4B · P4C
  • electro-pneumatic proportional regulators
  • series P4B, P4C (EPP4)
  • Basic, Comfort, Comfort ATEX
  • service and spares for legacy EPP3 units
To the series →
Coils and accessories

Solenoid coils, housings and connectors

Parker ZB · WB · JB · 481–496
  • coil groups ZB, WB, JB et al.
  • explosion-protected versions (Ex/ATEX)
  • voltages 12 V DC to 230 V AC
  • DIN plugs, housings, accessories
To the series →
Spare parts

Spare-part and repair kits

Parker 7K · Rebuild-Kits
  • repair and rebuild kits
  • plunger assemblies, springs, diaphragms
  • for 121/131/321/341, Gold Ring, F and HP series
  • matched via the valve part number
To the series →
Instrumentation tube fittings

A-LOK® two-ferrule tube fittings

Parker A-LOK
  • Tube OD 1/16" to 2", metric 2 to 32 mm
  • Suparcase® hardened back ferrule resists vibration fatigue
  • Molybdenum-disulfide coated nut prevents galling
  • Options incl. oxygen cleaning (C3), NACE-compliant material, certified nuclear quality (CNQ)
Stated in the catalogue: tube OD 1/16" to 2", metric 2 to 32 mm
To the series →
Instrumentation tube fittings

CPI™ single-ferrule tube fittings

Parker CPI
  • Tube OD 1/16" to 2", metric 2 to 32 mm
  • 316 stainless steel standard with HTC traceability, other materials available
  • Silver-plated nut thread prevents galling
  • Interchangeable with common other makes (reference in every ordering table)
Stated in the catalogue: tube OD 1/16" to 2", metric 2 to 32 mm
To the series →
Pipe & adapter fittings

Instrumentation pipe fittings and ISO adapters

Parker NPT/ISO
  • NPT sizes 1/16" to 2"
  • Materials: 316 stainless steel, brass, steel
  • Rolled male threads for extra strength
  • ISO/BSP adapters (taper and parallel) incl. sealing washers
Stated in the catalogue: NPT sizes 1/16" to 2", ISO/BSP adapters
To the series →
Pipe & adapter fittings

10k high-pressure pipe fittings

Parker SSHP
  • Rated 10,000 psi (690 bar) at 22 °C
  • 316L stainless steel, part number suffix -SSHP
  • NPT threads to ANSI B1.20.1
  • Nipples, adapters, couplings, elbows, tees and crosses
Stated in the catalogue: 10,000 psi (690 bar) at 22 °C; AISI 316L −255 °C to 649 °C
To the series →
Instrumentation tube fittings

Phastite® permanent tube connections

Parker PH
  • Up to 22,500 psi (1,550 bar)
  • Temperature range -45 °C to 93 °C
  • Tube OD 1/4" to 1" or 6 to 25 mm, wall 0.035" to 0.188"
  • Materials: 316 SS, Inconel® 625, Incoloy® 825, Super Duplex
Stated in the catalogue: up to 22,500 psi (1,550 bar), −45 °C to 93 °C
To the series →
Instrumentation tube fittings

MPI™ medium-pressure instrumentation fittings

Parker MP7
  • Working pressure up to 15,000 psi
  • Sizes 1/4" to 1" (including 9/16")
  • Suparcase® hardened front and back ferrules
  • Inverted nut with molybdenum-disulfide coating
Stated in the catalogue: working pressure up to 15,000 psi
To the series →
Tubing & materials

316/316L instrumentation tubing

Parker TUBE-316
  • 316/316L material
  • Outside diameters 1/4" to 1"
  • Wall thicknesses .028" to .120"
  • Fully traceable to source
To the series →
Tube working tools

Tube working and assembly tools

Parker PT
  • PTB tube benders: imperial 1/4" to 1/2", metric 6 to 12 mm
  • PT-D/PT-DL deburring tools for 1/4" to 2" or 6 to 50 mm
  • Tru-Kut sawing guide PT-V for square cuts (±1°)
  • Pre-assembly and marking tools (PPT, PTM) for correct insertion depth
To the series →
Ball valves

Ball and needle valves Series B

Parker 4121-BV
  • 2- and 3-way
  • up to 207 bar
  • 316 stainless
  • compression/thread/tube
Stated in the catalogue: up to 207 bar; compression, threaded and pipe connections
To the series →

Not sure which version fits?

Give us medium, pressure, temperature and connection. You receive a proposal with data sheet and availability, usually within 24 hours on business days (for standard series).